When it comes to bacterial growth, factors such as temperature and humidity play a big role. By introducing a humidity regulation system to counter bacterial growth, this problem will be mitigated. Prior to the introduction of PID controllers or Proportional-Integral-Derivative controllers, the traditional approach to systems is to manually check for each parameter in a loop before a system can proceed to its next step. Repeatedly inspecting each parameter in the loop for errors becomes tedious, expensive, and time-consuming. This is where PID controllers become an important tool as it is a type of controller in a system that checks for the difference between the measured process and the desired setpoint. By doing so, corrective measures can be taken by the controller to allow the system consistently to produce the desired output and avoid errors. Other research done in the field focuses on controlling temperature and humidity using PID controllers and applying them in different enclosure systems. The researchers designed a simpler method of optimizing said PID controller for the purpose of adjusting the parameters such as temperature or humidity. The code created takes a transfer function coefficient input from a user, a PID controller coefficient input, an input of desired output, and use all these to be able to optimize a system. To do this, a MATLAB Simulink program is created to take inputs and produce desired results. The optimal parameters for maintaining consistent humidity levels were determined. Additionally, the simulations aided in providing observations on the system’s behavior in different conditions.
Keywords: PID controller; transfer function; control system; error correction; humidity; regulationA. Abdulameer, M. Sulaiman, M. Aras, and D. Saleem, “Tuning Methods of PID Controller for DC Motor Speed Control,” Indonesian Journal of Electrical Engineering and Computer Science, vol. 3, no. 2, p. 343, Aug. 2016, doi: https://doi.org/10.11591/ijeecs.v3.i2.pp343-349.
A. R. Haron and N. R. N. Idris, “Simulation of MRAS-based Speed Sensorless Estimation of Induction Motor Drives using MATLAB/SIMULINK,” 2006 IEEE International Power and Energy Conference, Putra Jaya, Malaysia, 2006, pp. 411-415, doi: 10.1109/PECON.2006.346686.
Boghossian, A., Brown, J., Zak, S. “P, I, D, PI, PD, AND PID control”. LibreTexts Engineering. 2022, May 23.
B. Deo Kumar, A. Kushwaha, A. Kumar and A. Agarwal, “Design & Implementation of Digital Guitar Tuner Using MATLAB,” 2021 International Conference on Advance Computing and Innovative Technologies in Engineering (ICACITE), Greater Noida, India, 2021, pp. 547-549, doi: 10.1109/ICACITE51222.2021.9404728.
Electrical Technology. “What is a PID Controller? Its types, Working, and Applications”. n.d.
F. C. Teng, “Real-time control using MATLAB Simulink,” Smc 2000 conference proceedings. 2000 ieee international conference on systems, man and cybernetics. ‘cybernetics evolving to systems, humans, organizations, and their complex interactions’ (cat. no.0, Nashville, TN, USA, 2000, pp. 2697-2702 vol.4, doi: 10.1109/ICSMC.2000.884403.
Humidity, and Temperature on Bacterial Growth and Bacterial Genera Distribution”. Int. J. Environ. Res. Public Health 2022, 19, 15345. https://doi.org/10.3390/ijerph192215345
Jamil, A. A., Tu, W. F., Ali, S. W., Terriche, Y., and Guerrero, J. M. “Fractional-Order PID Controllers for Temperature Control: A Review. Energies”, 15(10), 3800. MDPI AG, 2022. http://dx.doi.org/10.3390/en15103800
Kinney, T., Gerry, J., Buckbee, G. “Benefits of Controller Monitoring and Integrated PID Optimization”. 2005.
K.-S. Tang, K. F. Man, G. Chen, and S. Kwong, ‘An optimal fuzzy PID controller’, IEEE transactions on industrial electronics, vol. 48, no. 4, pp. 757–765, 2001.
L. Wang, PID control system design and automatic tuning using MATLAB/Simulink. John Wiley & Sons, 2020.
Matamoros, M., Gómez-Blanco, J. C., Sánchez, Á. J., Mancha, E., Marcos, A. C., Carrasco-Amador, J. P., and Pagador, J. B. “Temperature and Humidity PID Controller for a Bioprinter Atmospheric Enclosure System”. Micromachines. 11(11), 999. MDPI AG, 2020. http://dx.doi.org/10.3390/mi11110999
MathWorks. “Transfer Function”. n.d.
M. H. Moradi, ‘New techniques for PID controller design’, in Proceedings of 2003 IEEE Conference on Control Applications, 2003. CCA 2003., 2003, vol. 2, pp. 903–908.
Y. Qiu et al., “The Effects of Ventilation, Humidity, and Temperature on Bacterial Growth and Bacterial Genera Distribution,” International Journal of Environmental Research and Public Health, vol. 19, no. 22, p. 15345, Nov. 2022, doi: https://doi.org/10.3390/ijerph192215345.
R. P. Borase, D. K. Maghade, S. Y. Sondkar, and S. N. Pawar, ‘A review of PID control, tuning methods and applications’, International Journal of Dynamics and Control, vol. 9, pp. 818–827, 2021.
Sterling E.M., Arundel, A., and Sterling, T. D., “Criteria for Human Exposure to Humidity in Occupied Buildings”. Vol. 91, Part 1. ASHRAE Transactions, 1985.
Smart Fog. “Humidity Control Systems - Clean Room Humidity Control”. n.d.
S. Unsdorfer. “Managing Ideal Indoor Humidity for Maximum Comfort”. Oct. 27, 2016. https://www.centralhtg.com/blog/managing-home-humidity-for-maximum-comfort
Jianxin Tang, “PID controller using the TMS320C31 DSK with online parameter adjustment for real-time DC motor speed and position control,” ISIE 2001. 2001 IEEE International Symposium on Industrial Electronics Proceedings (Cat. No.01TH8570), Pusan, Korea (South), 2001, pp. 786-791 vol.2, doi: 10.1109/ISIE.2001.931568.
Y. WANG, H. LIU, and C. WANG, “Design of fuzzy self-tuning PID controller based on field programmable analog array,” Journal of Computer Applications, vol. 31, no. 2, pp. 466–469, Apr. 2011, doi: https://doi.org/10.3724/sp.j.1087.2011.00466.